Scientific article
English

Comparison of ocular hemodynamics measured by a new retinal blood flowmeter and color Doppler imaging

Published inOphthalmic Surgery, Lasers & Imaging, vol. 34, no. 4, p. 342-347
Publication date2003
Abstract

Background and objective: To compare measurements of a new retinal blood flow device with central retinal artery blood velocity. Materials and methods: One randomly selected eye from each of 13 subjects was examined. Blood flow was measured by laser blood flowmeter and velocity by color Doppler imaging. The correlation between measurements was analyzed using regression analysis where a P value of less than .05 and coefficient of regression values of greater than .5 were considered significant. Results: The laser blood flowmeter produced vessel diameter measurements of 90.1 +/- 18.7 microm (mean +/- standard deviation), velocity of 19.7 +/- 8.06 mm/sec, and flow measurements of 4.24 +/- 2.41 microL/min. Central retinal artery peak systolic velocity, end diastolic velocity, and mean velocity correlated significantly with laser blood flowmeter velocity (P = .01, r = .66; P < .01, r = .77; and P = .003, r = .76, respectively) and flow (P = .01, r = .71; P = .03, r = .6; and P = .01, r = .69, respectively). Conclusions: The laser blood flowmeter produces retinal artery flow and velocity measurements that correlate with central retinal artery peak systolic velocity end diastolic velocity, and mean velocity measurements. Further validation of the laser blood flowmeter's accuracy in measuring real flow warranted and likely requires more invasive in vivo studies (in animal models). However, this study supports the ability of the laser blood flowmeter to measure retinal blood flow.

Keywords
  • Adult
  • Blood Flow Velocity
  • Eye/blood supply/diagnostic imaging
  • Female
  • Hemodynamics
  • Humans
  • Lasers
  • Male
  • Regional Blood Flow
  • Retinal Vessels/physiology
  • Rheology
  • Ultrasonography
  • Doppler
  • Color
Affiliation entities Not a UNIGE publication
Citation (ISO format)
KAGEMANN, Larry et al. Comparison of ocular hemodynamics measured by a new retinal blood flowmeter and color Doppler imaging. In: Ophthalmic Surgery, Lasers & Imaging, 2003, vol. 34, n° 4, p. 342–347.
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
Journal ISSN1542-8877
167views
0downloads

Technical informations

Creation26/08/2021 14:54:00
First validation26/08/2021 14:54:00
Update16/03/2023 01:14:00
Status update16/03/2023 01:13:58
Last indexation31/10/2024 23:00:46
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack