Enantiomeric methadone quantitation on real post-mortem dried matrix spots samples: Comparison of liquid chromatography and supercritical fluid chromatography coupled to mass spectrometry

Published inJournal of Chromatography. B, vol. 1177, 122755
Publication date2021
Abstract

This study describes two bioanalytical methods for the quantitation of the two methadone enantiomers in dried matrix spots using high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) and high performance supercritical chromatography tandem mass spectrometry (HPSFC-MS/MS). Dried matrix spots were obtained by spotting 10 µL of each sample fluid on a Whatman paper. Methadone and its main metabolite, EDDP, were extracted with 100 µL methanol and subsequently injected into the LC-MS/MS and SFC-MS/MS systems. Enantiomeric separation was achieved with AGP-column for the LC conditions and with Chiralpak IH-3 in SFC. The two methods were fully validated and 93 post-mortem samples were analysed with both analytical methods. Results from validation parameters and results obtained for all post-mortem samples were compared with a significant spearman correlation of rs = 0.9978 for R-methadone and rs = 0.9981 for S-methadone. The LC method provided better results in terms of uncertainty, retention factor and resolution, whereas SFC provides better sensitivity, with lower LOD. Median R-/S-methadone ratio in peripheral blood was found equal to 1.60 (N = 32), varying from 0.79 to 4.23. The reported values were in good agreement with previously published results. Based on the results obtained here, SFC-MS/MS can be considered a reliable alternative to the widely used LC-MS/MS for the quantitation of methadone enantiomers in bioanalysis and should be evaluated for other bioanalytical methods. Both methods can be easily and quickly used in toxicological routine analysis for the methadone quantitation in human fluids matrices, even if considering that the polysaccharide coated column IH-3 used in SFC does not allow the enantiomeric EDDP separation.

Keywords
  • Liquid chromatography
  • Supercritical fluid chromatography
  • Dried blood spots
  • Post-mortem
  • Chiral methadone quantitation
Citation (ISO format)
MUELLER, Françoise et al. Enantiomeric methadone quantitation on real post-mortem dried matrix spots samples: Comparison of liquid chromatography and supercritical fluid chromatography coupled to mass spectrometry. In: Journal of Chromatography. B, 2021, vol. 1177, p. 122755. doi: 10.1016/j.jchromb.2021.122755
Main files (1)
Article (Published version)
Identifiers
ISSN of the journal1570-0232
156views
53downloads

Technical informations

Creation06/30/2021 4:29:00 PM
First validation06/30/2021 4:29:00 PM
Update time03/16/2023 12:51:59 AM
Status update03/16/2023 12:51:57 AM
Last indexation02/12/2024 1:28:06 PM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack