Direct Potentiometric Sensing of Anion Concentration (Not Activity)

Published inACS Sensors, vol. 5, no. 2, p. 313-318
Publication date2020
Abstract

Potentiometric probes used in direct potentiometry are attractive sensing tools. They give information on ion activities, which is often uniquely useful. If, instead, concentrations are desired as sensor output, the ionic strength of the sample must be precisely known, which is often not possible. Here, for the first time, direct potentiometry can be made to report concentrations, rather than activities. It is demonstrated for the detection of monovalent anionic species by using a self-referencing Ag/AgI pulstrode as the reference element instead of a traditional reference electrode. This reference pulstrode releases a discrete quantity of iodide ions from the electrode and the resulting reference potential varies with the activity coefficient of iodide. The effects of activity coefficient on the indicator and reference electrode are therefore compensated and the observed cell potential may now be described in a Nernstian manner against anion concentration, rather than activity. Theoretical simulations and experimental results support the validity of this approach. For most monovalent anions of practical relevance, the potential difference between this approach and from a traditional activity coefficient calculation is less than 0.5 mV. The concept is validated with an all-solid-state nitrate sensor as well as a commercial fluoride-selective electrode, giving Nernstian responses in different ionic strength backgrounds against concentration without the need for correcting activity coefficients or liquid junction potentials.

Keywords
  • Direct potentiometry
  • Concentration and activity
  • Pulstrodes
  • Reference electrode
  • Local iodide release
Research groups
Funding
  • Swiss National Science Foundation - FN 200021_175622
  • Autre - National Natural Science Foundation of China (21874063)
Citation (ISO format)
GAO, Wenyue, XIE, Xiaojiang, BAKKER, Eric. Direct Potentiometric Sensing of Anion Concentration (Not Activity). In: ACS Sensors, 2020, vol. 5, n° 2, p. 313–318. doi: 10.1021/acssensors.9b02523
Main files (1)
Article (Accepted version)
accessLevelPublic
Identifiers
Additional URL for this publicationhttps://pubs.acs.org/doi/10.1021/acssensors.9b02523
Journal ISSN2379-3694
318views
197downloads

Technical informations

Creation08/06/2020 10:46:00
First validation08/06/2020 10:46:00
Update30/03/2023 11:04:51
Status update30/03/2023 11:04:50
Last indexation31/10/2024 18:50:12
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack