Scientific article
English

Thermal analysis of five unglazed solar collector systems for the heating of outdoor swimming pools

Published inSolar Energy, vol. 53, no. 1, p. 27-32
Publication date1994
Abstract

The performance and behavior of five unglazed solar collector installations, devoted to the heating of five outdoor swimming pools located in Switzerland, is studied on the basis of experimental data collected in 1988. Due to the low temperatures involved, hourly efficiencies often exceed 80%. The mean daily collector efficiency is of the order of 60% in optimal conditions and is in good agreement with the G3 simulation program.

Citation (ISO format)
MOLINEAUX, Benoît, LACHAL, Bernard Marie, GUISAN, Olivier. Thermal analysis of five unglazed solar collector systems for the heating of outdoor swimming pools. In: Solar Energy, 1994, vol. 53, n° 1, p. 27–32. doi: 10.1016/S0038-092X(94)90600-9
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
ISSN of the journal0038-092X
329views
0downloads

Technical informations

Creation05/21/2019 12:33:00 PM
First validation05/21/2019 12:33:00 PM
Update time03/15/2023 4:31:56 PM
Status update03/15/2023 4:31:56 PM
Last indexation10/31/2024 1:29:43 PM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack