Thermal analysis of five unglazed solar collector systems for the heating of outdoor swimming pools

Authors
Published in Solar Energy. 1994, vol. 53, no. 1, p. 27-32
Abstract The performance and behavior of five unglazed solar collector installations, devoted to the heating of five outdoor swimming pools located in Switzerland, is studied on the basis of experimental data collected in 1988. Due to the low temperatures involved, hourly efficiencies often exceed 80%. The mean daily collector efficiency is of the order of 60% in optimal conditions and is in good agreement with the G3 simulation program.
Identifiers
Full text
Structures
Research groups Systèmes énergétiques
ISE Energie
ISE Pôle Sciences
Citation
(ISO format)
MOLINEAUX, Benoît, LACHAL, Bernard Marie, GUISAN, Olivier. Thermal analysis of five unglazed solar collector systems for the heating of outdoor swimming pools. In: Solar Energy, 1994, vol. 53, n° 1, p. 27-32. doi: 10.1016/S0038-092X(94)90600-9 https://archive-ouverte.unige.ch/unige:117875