Synchrotron Imaging Shows Effect of Ventilator Settings on Intrabreath Cyclic Changes in Pulmonary Blood Volume

Published inAmerican Journal of Respiratory Cell and Molecular Biology, vol. 57, no. 4, p. 459-467
Publication date2017
Abstract

Despite the importance of dynamic changes in the regional distributions of gas and blood during the breathing cycle for lung function in the mechanically ventilated patient, no quantitative data on such cyclic changes are currently available. We used a novel gated synchrotron computed tomography imaging to quantitatively image regional lung gas volume (Vg), tissue density, and blood volume (Vb) in six anesthetized, paralyzed, and mechanically ventilated rabbits with normal lungs. Images were repeatedly collected during ventilation and steady-state inhalation of 50% xenon, or iodine infusion. Data were acquired in a dependent and nondependent image level, at zero end-expiratory pressure (ZEEP) and 9 cm H2O (positive end-expiratory pressure), and a tidal volume (Vt) of 6 ml/kg (Vt1) or 9 ml/kg (Vt2) at an Inspiratory:Expiratory ratio of 0.5 or 1.7 by applying an end-inspiratory pause. A video showing dynamic decreases in Vb during inspiration is presented. Vb decreased with positive end-expiratory pressure (P = 0.006; P = 0.036 versus Vt1-ZEEP and Vt2-ZEEP, respectively), and showed larger oscillations at the dependent image level, whereas a 45% increase in Vt did not have a significant effect. End-inspiratory Vb minima were reduced by an end-inspiratory pause (P = 0.042, P = 0.006 at nondependent and dependent levels, respectively). Normalized regional Vg:Vb ratio increased upon inspiration. Our data demonstrate, for the first time, within-tidal cyclic variations in regional pulmonary Vb. The quantitative matching of regional Vg and Vb improved upon inspiration under ZEEP. Further study is underway to determine whether these phenomena affect intratidal gas exchange.

Keywords
  • Animals
  • Blood Volume
  • Female
  • Image Interpretation
  • Computer-Assisted
  • Inhalation
  • Lung/blood supply/diagnostic imaging/physiopathology
  • Male
  • Rabbits
  • Respiration
  • Artificial
  • Synchrotrons
  • Ventilators
  • Mechanical
Citation (ISO format)
PORRA, Liisa et al. Synchrotron Imaging Shows Effect of Ventilator Settings on Intrabreath Cyclic Changes in Pulmonary Blood Volume. In: American Journal of Respiratory Cell and Molecular Biology, 2017, vol. 57, n° 4, p. 459–467. doi: 10.1165/rcmb.2017-0007OC
Main files (1)
Article (Published version)
accessLevelPublic
Identifiers
ISSN of the journal1044-1549
362views
260downloads

Technical informations

Creation09/18/2018 2:42:00 PM
First validation09/18/2018 2:42:00 PM
Update time03/15/2023 1:51:28 PM
Status update03/15/2023 1:51:27 PM
Last indexation01/17/2024 4:09:35 AM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack