What is the best glenoid configuration in onlay reverse shoulder arthroplasty? |
|
Authors | ||
Published in | International Orthopaedics. 2018 | |
Abstract | The purpose of this study was to analyze the effect of different glenoid configurations on arm position and range of motion (ROM) following reverse shoulder arthroplasty (RSA). The hypothesis was that different glenoid configurations would lead to changes in humeral offset, acromio-humeral distance (AHD), ROM, and rotator cuff muscle length. | |
Keywords | Arm position — Complications — Glenoid offset — Muscle tension — Onlay design — Range of motion — Reverse total shoulder arthroplasty | |
Identifiers | PMID: 29492611 | |
Full text | ||
Structures | ||
Research group | Thérapie cellulaire et troubles musculo-squelettiques (960) | |
Citation (ISO format) | LAEDERMANN, Alexandre et al. What is the best glenoid configuration in onlay reverse shoulder arthroplasty?. In: International Orthopaedics, 2018. doi: 10.1007/s00264-018-3850-x https://archive-ouverte.unige.ch/unige:103654 |