Abstract

Essentials Accurate determination of anticoagulant plasma concentration is important in clinical practice. We studied the accuracy and consistency of anti-Xa assays for rivaroxaban in a multicentre study. In a range between 50 and 200 μg L-1 , anti-Xa activity correlated well with plasma concentrations. The clinical value might be limited by overestimation and intra- and inter-individual variation.

Citation (ISO format)
STUDT, J-D et al. Accuracy and consistency of anti-Xa activity measurement for determination of rivaroxaban plasma levels. In: Journal of Thrombosis and Haemostasis, 2017, vol. 15, n° 8, p. 1576–1583. doi: 10.1111/jth.13747