Scientific article
OA Policy
English

Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction

Published inPhysics in medicine and biology, vol. 61, no. 15, p. 5456-5485
Publication date2016
Abstract

Whole-body (WB) dynamic PET has recently demonstrated its potential in translating the quantitative benefits of parametric imaging to the clinic. Post-reconstruction standard Patlak (sPatlak) WB graphical analysis utilizes multi-bed multi-pass PET acquisition to produce quantitative WB images of the tracer influx rate K i as a complimentary metric to the semi-quantitative standardized uptake value (SUV). The resulting K i images may suffer from high noise due to the need for short acquisition frames. Meanwhile, a generalized Patlak (gPatlak) WB post-reconstruction method had been suggested to limit K i bias of sPatlak analysis at regions with non-negligible (18)F-FDG uptake reversibility; however, gPatlak analysis is non-linear and thus can further amplify noise. In the present study, we implemented, within the open-source software for tomographic image reconstruction platform, a clinically adoptable 4D WB reconstruction framework enabling efficient estimation of sPatlak and gPatlak images directly from dynamic multi-bed PET raw data with substantial noise reduction. Furthermore, we employed the optimization transfer methodology to accelerate 4D expectation-maximization (EM) convergence by nesting the fast image-based estimation of Patlak parameters within each iteration cycle of the slower projection-based estimation of dynamic PET images. The novel gPatlak 4D method was initialized from an optimized set of sPatlak ML-EM iterations to facilitate EM convergence. Initially, realistic simulations were conducted utilizing published (18)F-FDG kinetic parameters coupled with the XCAT phantom. Quantitative analyses illustrated enhanced K i target-to-background ratio (TBR) and especially contrast-to-noise ratio (CNR) performance for the 4D versus the indirect methods and static SUV. Furthermore, considerable convergence acceleration was observed for the nested algorithms involving 10-20 sub-iterations. Moreover, systematic reduction in K i % bias and improved TBR were observed for gPatlak versus sPatlak. Finally, validation on clinical WB dynamic data demonstrated the clinical feasibility and superior K i CNR performance for the proposed 4D framework compared to indirect Patlak and SUV imaging.

Citation (ISO format)
KARAKATSANIS, Nicolas A et al. Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction. In: Physics in medicine and biology, 2016, vol. 61, n° 15, p. 5456–5485. doi: 10.1088/0031-9155/61/15/5456
Main files (1)
Article (Published version)
accessLevelPublic
Identifiers
ISSN of the journal0031-9155
435views
562downloads

Technical informations

Creation11/24/2016 3:53:00 PM
First validation11/24/2016 3:53:00 PM
Update time03/15/2023 1:14:21 AM
Status update03/15/2023 1:14:21 AM
Last indexation10/31/2024 5:45:01 AM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack