en
Scientific article
English

A novel approach to reducing number of sensing units for wearable gait analysis systems

Published inIEEE transactions on biomedical engineering, vol. 60, no. 1, p. 72-77
Publication date2013
Abstract

Gait analysis methods to estimate spatiotemporal measures, based on two, three or four gyroscopes attached on lower limbs have been discussed in the literature. The most common approach to reduce the number of sensing units is to simplify the underlying biomechanical gait model. In this study, we propose a novel method based on prediction of movements of thighs from movements of shanks. Datasets from three previous studies were used. Data from the first study (ten healthy subjects and ten with Parkinson's disease) were used to develop and calibrate a system with only two gyroscopes attached on shanks. Data from two other studies (36 subjects with hip replacement, seven subjects with coxarthrosis, and eight control subjects) were used for comparison with the other methods and for assessment of error compared to a motion capture system. Results show that the error of estimation of stride length compared to motion capture with the system with four gyroscopes and our new method based on two gyroscopes was close ( -0.8 ±6.6 versus 3.8 ±6.6 cm). An alternative with three sensing units did not show better results (error: -0.2 ±8.4 cm). Finally, a fourth that also used two units but with a simpler gait model had the highest bias compared to the reference (error: -25.6 ±7.6 cm). We concluded that it is feasible to estimate movements of thighs from movements of shanks to reduce number of needed sensing units from 4 to 2 in context of ambulatory gait analysis.

Keywords
  • Aged
  • Arthroplasty, Replacement, Hip
  • Case-Control Studies
  • Clothing
  • Female
  • Gait/physiology
  • Humans
  • Male
  • Middle Aged
  • Models, Biological
  • Monitoring, Ambulatory/instrumentation/methods
  • Parkinson Disease/physiopathology
  • Signal Processing, Computer-Assisted
Citation (ISO format)
SALARIAN, Arash et al. A novel approach to reducing number of sensing units for wearable gait analysis systems. In: IEEE transactions on biomedical engineering, 2013, vol. 60, n° 1, p. 72–77. doi: 10.1109/TBME.2012.2223465
Main files (1)
Article (Published version)
accessLevelRestricted
Identifiers
ISSN of the journal0018-9294
571views
0downloads

Technical informations

Creation01/02/2014 4:47:00 PM
First validation01/02/2014 4:47:00 PM
Update time03/14/2023 8:53:29 PM
Status update03/14/2023 8:53:29 PM
Last indexation05/02/2024 1:44:43 PM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack