ArUco‐based stylus reliability for reproductible 3D digitalisation of shoulder cartilage contours

Published inJournal of anatomy, vol. 244, no. 4, p. 620-627
Publication date2024-04
First online date2024-01-12
Abstract

Imaging techniques in anatomy have developed rapidly over the last decades through the emergence of various 3D scanning systems. Depending on the dissection level, non‐contact or tactile contact methods can be applied on the targeted structure. The aim of this study was to assess the inter and intra‐observer reproducibility of an ArUco‐based localisation stylus, that is, a manual technique on a hand‐held stylus. Ten fresh–frozen, unembalmed adult arms were used to digitalise the glenoid cartilage related to the glenohumeral joint and the contour of the clavicle cartilage related to the acromioclavicular joint. Three operators performed consecutive digitalisations of each cartilage contour using an ArUco‐based localisation stylus recorded by a single monocular camera. The shape of each cartilage was defined by nine shape parameters. Intra‐observer repeatability and inter‐observer reproducibility were computed using an intra‐class correlation (ICC) for each of these parameters. Overall, 35.2 ± 2.4 s and 26.6 ± 10.2 s were required by each examiner to digitalise the contour of a glenoid and acromioclavicular cartilage, respectively. For most parameters, good‐to‐excellent agreements were observed concerning intra‐observer (ICC ranging between 0.81 and 1.00) and inter‐observer (ICC ranging between 0.75 and 0.99) reproducibility. To conclude, through a fast and versatile process, the use of an ArUco‐based localisation stylus can be a reliable low‐cost alternative to conventional imaging methods to digitalise shoulder cartilage contours.

eng
Keywords
  • 3D digitalisation
  • ArUco markers
  • Cartilage
  • Hand-held stylus
  • Shoulder
  • Adult
  • Humans
  • Observer Variation
  • Reproducibility of Results
  • Shoulder Joint
Citation (ISO format)
MOISSENET, Florent et al. ArUco‐based stylus reliability for reproductible 3D digitalisation of shoulder cartilage contours. In: Journal of anatomy, 2024, vol. 244, n° 4, p. 620–627. doi: 10.1111/joa.13987
Main files (1)
Article (Published version)
Identifiers
ISSN of the journal0021-8782
28views
5downloads

Technical informations

Creation02/06/2024 7:51:27 PM
First validation07/04/2024 10:20:19 AM
Update time07/04/2024 10:20:19 AM
Status update07/04/2024 10:20:19 AM
Last indexation07/04/2024 10:20:40 AM
All rights reserved by Archive ouverte UNIGE and the University of GenevaunigeBlack